The default IP address of the ODP is 192.168.0.192
At any time you can check the IP configuration by pressing the button next to the Ethernet port
By pressing it one time, a ticket will be printed with MAC Address, IP Address, SubMask and GateWay.
By pressing it 10 seconds with the ODP powered on, you can reset the Ethernet configuration to default settings.
To modify the Ethernet configuration you need the configuration utility:
Select Ethernet Printer Configuration:
Select search to find the ODP (it must be on the same network of the computer with the utility)
Once the printer is found you can modify the IP, Submask and gateway manually or use the DHCP function.
Click on Save to save the settings in the printer
You can check the configuration with the test button or with the button next to the Ethernet port.